Emulators
R-L Load
Power Inverter Module TestingProduction and EMI testing of power inverter modules.
Specifications
- Dual Channel
- Same Controller and Interface as Gen2 EME
- EDAC I/O Interface
- Position Sensing Emulation
- Resolver Lobes (2 to 24)
- Resolver Offset (-2pi to 2pi radians)
- Resolver Excitation (3kHz to 20kHz)
- Encoder Pulses (up to 80 pulses/revolution)
- Flux tables not required (but can be present)
- Reporting of currents and temperatures
- Power: 20kW/channel
- Inductance: 105uH (same inductor as EME)
- Resistance: 55 mOhm/phase (others available)
- Phase Current: 350Arms/ph max
- PIM Control Power: (8 to 30VDC) available as option
- Protections: Overtemp/no water flow shutdown/ESTOP/HVL/Interlock/Loss of CAN
Facility Requirements
- 1 Phase Service (120/60Hz)
- Coolant: Water or 50% WEG, 30C Max, 2.5 GPM/Ch min.
- Dimensions: 584.2 x 990.6 x 1016 (WxDxH millimeters)